    Optical Direct Reading Meter
    • Optical direct reading valve control meter
    • 6 光电直读阀控水表--.jpg
    • 6 光电直读阀控水表---.jpg

    Optical direct reading valve control meter

    Type:Optical Direct Reading Meter

    Introduction:Photoelectric direct-reading valve control water meter uses optical direct reading technology to read the wheel data, compared with the traditional pulse table, it can reduce the reading error to zero, automatic meter reading system is zero-error electromechan...

    Service Hotline:400 992 5080

    PurchaseOnline consultation

    • Description
    • Parameter

    Product use

    Photoelectric direct-reading valve control water meter uses optical direct reading technology to read the wheel data, compared with the traditional pulse table, it can reduce the reading error to zero, automatic meter reading system is zero-error electromechanical conversion electronic remote meter, And the use of low-power design, usually without power supply, only meter reading or valve when it needs to be powered.


    PRODUCT FEATURES



    This series of remote water meter for the dry structure.

    Convenient reading, long-term clarity.

    Optical encoding passive direct reading technology.

    Valve can control water.

    TECHNICAL PARAMETER


    Product Type: LXS-15 ~ 25 FK
    Working voltage: DC 36V
    Meter reading current ≤ 9.0mA
    Static working current ≤1.3 mA



    Valve on/off bus current ≤50 mA
    Valve on/off motor valve input current≤30mA
    Water temperature: 0.1℃ ~ +45 ℃
    Humidity: 0~95% RH


    Storage temperature: -25 ℃ ~ +65 ℃
    Temperature class: T50 (cold water) T90 (hot water)
    The maximum allowable water pressure: 1 MPa
    Maximum pressure loss: 0.063 Mpa



    Valve Type: Motor Valve
    Communication with the host computer: M-bus field bus
    Communication transmission rate: 2400 baud





    Communication protocols: DL / T645, CJ / T 188 and internal protocols
    (Or user-specified protocol)
    Communication transmission maximum distance: 300m;
    (Communication line size AVVR2 × 0.75)

    Single table valve on / off time: 8S
    Bus pin ESD protection over 10kV
    Short circuit current protection
    For the bus open, short circuit, idle fault protection



    FLOW PARAMETERS

    Model

    Nominal diameter

    DN(MM)

    Accuracy

    grade

    Overload Q4
    Commonly used flow Q3
    Demarcation flow Q2
    Minimum flow Q1
    M3/H
    LXSY-15FK
    15 level 2 3.125
    2.5
    0.050
    0.030
    LXSY-20FK
    20 level 2
    5.00
    4.0
    0.080
    0.050
    LXSY-25FK
    25 level 2
    7.875
    6.3
    0.128
    0.080
    LXSY-40
    40 level 2
    20
    16
    0.320
    0.200
    Note: The maximum allowable error
    The maximum allowable error is ± 5% from the lower zone, including the minimum flow (Q1) to not including the boundary flow (Q2).
    The maximum allowable error from the high zone including the demarcation flow rate (Q2) to the maximum flow rate (Q4) is ± 2%.